UYGULAMA ALANLARI
- Isıtıcı Ev Aletleri
- Isıtma ve Kurutma Sistemleri
- Plastik Tekstil
- Demir Çelik
- Cam Seramik Endüstrilerinde
CONDUCTOR
- Red or tin-plated electrolytic annealed flexible copper wire
- Class-5 as per IEC 60228
INSULATION
- Silicone rubber
- Silicone impregnated glassfibre braid
- Type: EI2 EN 50363-1
TECHNIC DATA
- "-60/+200 °C" Continuous Working Temperature
- +230 °C Short time Max. Working Tempreature
- Resistance to sudden temperature change
- Resistance to UV
- Resistance to Ageing
- Working Voltage: 300/500 V
- Test Voltage: 2000 V
PACKAGE
Rolls, Plastic or Wood Drums
Nominal Section (mm2) |
Max. Conductor Diameter (mm) |
Max. Conductor Resistance | Insulated Diameter (mm) |
Thickness of Insulation (mm) |
Outer Diameter (mm ±0,10) |
Approximate Weight (gr/m) |
|
min. | max | ||||||
0,50 | 16X0,20 | 40,10 | 2,20 | 0,60 | 2,60 | 3,30 | 12,0 |
0,75 | 24X0,20 | 26,70 | 2,40 | 0,60 | 2,80 | 3,50 | 14,7 |
1,00 | 32X0,20 | 20,00 | 2,60 | 0,60 | 2,90 | 3,70 | 17,0 |
1,50 | 30X0,25 | 13,70 | 3,00 | 0,70 | 3,40 | 4,20 | 23,5 |
2,50 | 50X0,25 | 8,21 | 3,70 | 0,80 | 4,00 | 5,00 | 34,5 |
4,00 | 56X0,30 | 5,09 | 4,20 | 0,80 | 4,50 | 5,60 | 49,2 |
6,00 | 84X0,30 | 3,39 | 4,80 | 0,80 | 5,20 | 6,00 | 73,0 |
10,00 | 80X0,40 | 1,95 | 6,80 | 1,00 | 7,20 | 7,80 | 124,0 |
16,00 | 126X0,40 | 1,24 | 8,00 | 1,00 | 8,40 | 9,00 |
195,0 |